6A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 6A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

10A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 10A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

13A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 13A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

16A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 16A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

20A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 20A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

25A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 25A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

32A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 32A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

40A 30mA B RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 40A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve B * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

6A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 6A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

10A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 10A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

13A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 13A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

16A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 16A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

20A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 20A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

25A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 25A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

32A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 32A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

40A 30mA C RCBO/AFDD 1MW 1P+SWN

Technical Features: * Miniature AFDD/RCBO * BS EN 62606 * Current rating 40A * Serial arc fault detection * Parallel arc fault detection * Rated residual operating current 30mA * RCD type A * Tripping characteristic curve C * Pole configuration 1P+N (switched neutral) * Rated short circuit capacity 6kA * Plug in connection to the Starbreaker busbar system

Cat Number Description Pack Unit
B Curve
61/B0630AFD 6A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B1030AFD 10A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B1330AFD 13A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B1630AFD 16A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B2030AFD 20A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B2530AFD 25A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B3230AFD 32A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
61/B4030AFD 40A 30mA B RCBO/AFDD 1MW 1P+SWN 1 EACH
C Curve
61/C0630AFD 6A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C1030AFD 10A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C1330AFD 13A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C1630AFD 16A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C2030AFD 20A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C2530AFD 25A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C3230AFD 32A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
61/C4030AFD 40A 30mA C RCBO/AFDD 1MW 1P+SWN 1 EACH
Can’t find what your looking for? Then contact us at Electrium or email us.
Contact us/Order cataloguesfind a distributorFind your local contact
Crabtree Sales
01543 455010
[email protected]
Crabtree Technical
01543 438310
[email protected]
Export Sales
+44 1543 455049
[email protected]