2W P250 PB 630A Main Unit C/W TP Sw/U

* 630A rated Panelboards * 900mm wide x 250mm deep (including door) * Busbar fault rated 50kA for 1 sec * 250A outgoing TP MCCBs (T2 frame size) * IP3X (door closed) * Incoming connections Incomer: 32mm wide lug connections* Neutral: 30 x 6mm copper bar 1 x M8 connection Earth: 25 x 5mm copper bar 1 x M12 connection * BSEN/IEC 61439-2: 2009 Designation of the incoming device is defined by the selection of an overcurrent release or Switch Disconnector module. THE SWITCHING UNIT MUST BE FITTED WITH ONE OF THESE MODULES.

4W P250 PB 630A Main Unit C/W TP Sw/U

* 630A rated Panelboards * 900mm wide x 250mm deep (including door) * Busbar fault rated 50kA for 1 sec * 250A outgoing TP MCCBs (T2 frame size) * IP3X (door closed) * Incoming connections Incomer: 32mm wide lug connections* Neutral: 30 x 6mm copper bar 1 x M8 connection Earth: 25 x 5mm copper bar 1 x M12 connection * BSEN/IEC 61439-2: 2009 Designation of the incoming device is defined by the selection of an overcurrent release or Switch Disconnector module. THE SWITCHING UNIT MUST BE FITTED WITH ONE OF THESE MODULES.

6W P250 PB 630A Main Unit C/W TP Sw/U

* 630A rated Panelboards * 900mm wide x 250mm deep (including door) * Busbar fault rated 50kA for 1 sec * 250A outgoing TP MCCBs (T2 frame size) * IP3X (door closed) * Incoming connections Incomer: 32mm wide lug connections* Neutral: 30 x 6mm copper bar 1 x M8 connection Earth: 25 x 5mm copper bar 1 x M12 connection * BSEN/IEC 61439-2: 2009 Designation of the incoming device is defined by the selection of an overcurrent release or Switch Disconnector module. THE SWITCHING UNIT MUST BE FITTED WITH ONE OF THESE MODULES.

160A.400A Overcurrent Release

* 400A rated Panelboards * 900mm wide x 250mm deep (including door) * Busbar fault rated 35kA for 1 sec * 250A outgoing TP MCCBs (T2 frame size) * IP3X (door closed) * Incoming connections Incomer: 32mm wide lug connections* Neutral: 30 x 6mm copper bar 1 x M8 connection Earth: 25 x 5mm copper bar 1 x M12 connection * BSEN/IEC 61439-2: 2009 Designation of the incoming device is defined by the selection of an overcurrent release. THE SWITCHING UNIT MUST BE FITTED WITH ONE OF THESE MODULES. * Dependant on the type of cable lug selected, cables up to 300mm2 can be connected to these 32mm wide connections

250A.630A Overcurrent Release

* Adjustable overcurrent release * Adjustable short circuit release

Cat Number Description Pack Unit
630A Panelboard with TP Switching Unit
173T2632 2W P250 PB 630A Main Unit C/W TP Sw/U 0 EACH
173T2634 4W P250 PB 630A Main Unit C/W TP Sw/U 0 EACH
173T2636 6W P250 PB 630A Main Unit C/W TP Sw/U 0 EACH
Overcurrent Release & switch disconnector modules for TP Switching Unit
7T340OR3 160A.400A Overcurrent Release 0 EACH
7T363OR3 250A.630A Overcurrent Release 0 EACH
Can’t find what your looking for? Then contact us at Electrium or email us.
Contact us/Order cataloguesfind a stockistContact a sales engineer
Crabtree Sales
01543 455010
crabtree.sales@electrium.co.uk
Crabtree Technical
01543 438310
crabtree.technical@electrium.co.uk
Export Sales
+44 1543 455049
export@electrium.co.uk